Immersion Heater Power Reducer Datasheet

2015-10-17 14_14_43-Immersion Heater Power Reducer _ Reduce 3kW immersion to 1.5 kW or 2kW immersion

  • Power reducer (halve the power)
  • Easy installation
  • 1 year guarantee as standard
  • CE & RoHS compliant
  • British Design & Manufacture

TYPICAL APPLICATION
Immersion Heater

TECHNICAL SPECIFICATION

Units is designed to halve the power.
E.g. 3KW load reduced to 1.5KW.

INPUT
110 / 240Vac
May be suitable for other supply voltages up to 600Vac.
Frequency: 50Hz +/- 10% nominal, other ranges available.

OUTPUT LOAD
1 to 3 KW ( up to 13A max)

PROTECTION
Isolation between. LIVE / Case / Heat sink plate
Input over range: 20A (non repetitive)
Enclosure: IP65

immersion_power_reducer_wiring_diagram1

ENVIRONMENTAL CONDITION
Storage temperature: – 20 to +70 C
Operating Ambient: -20 to +70 C
Relative Humidity: 20 to 95% RH
MOUNTING & DIMENSION
Dimension : W44 x H90 x D24 (mm)
Wire : 300mm Length rated 20A max.
Mounting hole centre: 66mm (2 x 4.2mm hole dia)
Weight < 125g
Installation: CAT II

 

 

Buy Power Reducer Now